( ESNUG 282 Item 8 ) ------------------------------------------------ [2/26/98]

From: Eran Vodevoz <eran.vodevoz@analog.com>
Subject: Library Compiler Won't Take Discharge Cells

Hello John,

I have a problem/challenge - how to "feed" Library Compiler with discharge
cells?  As it was proposed in the course -- the general direction is to
define it as an ITS module.  I've been searching in the openbook ("Synopsys
On-Line Docs") for an example of discharge cells but I found none.

I would really appriciate if someone could send me an example of ITS format
with the required timing arcs (I mean the names/kinds of arcs -- not the
numbers) for a discharge cell.  Here is an example of a typical circuit:

                +---o NOUT
                |
                |
          EN---||
                |
                |---------+
           A---||         |
                |    B---||        
                |         |
                |         |
                |    C---||
                |         |
                |         |
                \/        \/

Let's say that the EN input is clock or "something & clock"

  - Eran Vodevoz
    Analog Devices        Hertzlia, Israel



 Sign up for the DeepChip newsletter.
Email
 Read what EDA tool users really think.


Feedback About Wiretaps ESNUGs SIGN UP! Downloads Trip Reports Advertise

"Relax. This is a discussion. Anything said here is just one engineer's opinion. Email in your dissenting letter and it'll be published, too."
This Web Site Is Modified Every 2-3 Days
Copyright 1991-2024 John Cooley.  All Rights Reserved.
| Contact John Cooley | Webmaster | Legal | Feedback Form |