( ESNUG 289 Item 10 ) ---------------------------------------------- [5/13/98]

Subject: ( ESNUG 287 #4 288 #9 ) Need 98.02 Ultra To Replace Old Commands?

> We're attempting to run 98.02 and have found an interesting requirement of
> another license (DC Ultra) in order to use one of the new commands that
> replaces an obsolete compilier option (prioritize_min_paths).
>
> set_cost_priority gives an error message.
>
> Has anyone else run into this problem?
>
>   - Mark Fox
>     Advanced Micro Devices


From: [ A Synopsys CAE ]

John,

The option "-prioritize_min_paths" in compile is still available for
backward compatibility.  This option has not been removed or moved to
DC Ultra.  With the new min/max optimization capability in Design
Compiler, there is less need to use the "prioritize_min_paths" option.
Thus, when you tried using it, the tool will generate a warning but
it will still optimize the design with min paths taken as a design rule.
This is to ensure that existing scripts using a 2-pass compile approach
for optimizing max and min separately will still work.

  - [ A Synopsys CAE ]