( ESNUG 348 Item 15 ) -------------------------------------------- [3/30/00]

Subject: ( ESNUG 344 #7 )  What About "set_dont_touch_network" On Resets?

> I want to thank Kayla for her observation on this issue.... I thought I
> was going crazy!!!  I've been compiling some blocks for a customer for a
> few months now and just recently I've noticed that since 99.10 that every
> once in a while it would NOT correctly listen to my set_dont_touch_network
> on a clock in a structural design....  The structural had 2 clocks, named
> CLK and CLK32FC.  The CLK32FC clock was correct while the CLK clock
> (redundant, I know...) was BUFFERED!  BUT, when I compiled this
> structural manually, the issue went away....  huh?
>
>     - Gzim Derti
>       Intrinsix Corp.                          Rochester, NY


From: Mark Grabosky <grabosky@mint-tech.com>

John,

I am having problems with the set_dont_touch_network not working on reset
nets with DC 99.10.  Kayla's ESNUG 344 #7 addressed this bug on clock nets.
Are there any workarounds for resets?

    - Mark Grabosky
      Mint Technologies



 Sign up for the DeepChip newsletter.
Email
 Read what EDA tool users really think.


Feedback About Wiretaps ESNUGs SIGN UP! Downloads Trip Reports Advertise

"Relax. This is a discussion. Anything said here is just one engineer's opinion. Email in your dissenting letter and it'll be published, too."
This Web Site Is Modified Every 2-3 Days
Copyright 1991-2024 John Cooley.  All Rights Reserved.
| Contact John Cooley | Webmaster | Legal | Feedback Form |

   !!!     "It's not a BUG,
  /o o\  /  it's a FEATURE!"
 (  >  )
  \ - / 
  _] [_     (jcooley 1991)