( ESNUG 348 Item 15 ) -------------------------------------------- [3/30/00]
Subject: ( ESNUG 344 #7 ) What About "set_dont_touch_network" On Resets?
> I want to thank Kayla for her observation on this issue.... I thought I
> was going crazy!!! I've been compiling some blocks for a customer for a
> few months now and just recently I've noticed that since 99.10 that every
> once in a while it would NOT correctly listen to my set_dont_touch_network
> on a clock in a structural design.... The structural had 2 clocks, named
> CLK and CLK32FC. The CLK32FC clock was correct while the CLK clock
> (redundant, I know...) was BUFFERED! BUT, when I compiled this
> structural manually, the issue went away.... huh?
>
> - Gzim Derti
> Intrinsix Corp. Rochester, NY
From: Mark Grabosky <grabosky@mint-tech.com>
John,
I am having problems with the set_dont_touch_network not working on reset
nets with DC 99.10. Kayla's ESNUG 344 #7 addressed this bug on clock nets.
Are there any workarounds for resets?
- Mark Grabosky
Mint Technologies
|
|